Mới nhất

3WJ1108-2AE42-1AA4-Z T40
0.0
Hết hàng
99.999.999 đ
Withdrawable circuit breaker with guide frame, IEC 60947-2, frame size 1, 4-poles, N-pole left, In=800A up to 440V AC 50/60Hz, breaking capacity S Icu=50kA at 440V, Trip unit ETU350WJ LSI Protection LT, ST, INST, rear connection horizontal, guide frame w/o shutter, Non-Automatic Breaker manual operating mechanism with mechanical request, without motorized operating mechanism, signaling switch ready-to-close, auxiliary switch (AUX) 2 NO+2 NC, without Closing coil (CC), manual operating mechanism with mechanical closing, without Remote trip alarm reset coil (RR), without 2nd shunt trip, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, Door sealing frame IP41
3WJ1108-2AE42-4DA4-Z T40
0.0
Hết hàng
99.999.999 đ
Withdrawable circuit breaker with guide frame, IEC 60947-2, frame size 1, 4-poles, N-pole left, In=800A up to 440V AC 50/60Hz, breaking capacity S Icu=50kA at 440V, Trip unit ETU350WJ LSI Protection LT, ST, INST, rear connection horizontal, guide frame w/o shutter, Non-Automatic Breaker with manual and motorized operating mechanism (M) 208-240 V AC / 220-250 V DC, Storage status and ready-to- close signaling switches, Auxiliary switches 2NO+2NC, Closing coil (CC) 100% OP 208-240 V AC / 220-250 V DC, applicable for continuous duty, without Remote trip alarm reset coil (RR), without 2nd shunt trip, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, Door sealing frame IP41
3WJ1108-2AE42-4DA4-Z R55+T40
0.0
Hết hàng
99.999.999 đ
Withdrawable circuit breaker with guide frame, IEC 60947-2, frame size 1, 4-poles, N-pole left, In=800A up to 440V AC 50/60Hz, breaking capacity S Icu=50kA at 440V, Trip unit ETU350WJ LSI Protection LT, ST, INST, rear connection horizontal, guide frame w/o shutter, Non-Automatic Breaker with manual and motorized operating mechanism (M) 208-240 V AC / 220-250 V DC, Storage status and ready-to- close signaling switches, Auxiliary switches 2NO+2NC, Closing coil (CC) 100% OP 208-240 V AC / 220-250 V DC, applicable for continuous duty, without Remote trip alarm reset coil (RR), without 2nd shunt trip, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, Mutual mechanical interlocking with 2 m bowden cable for circuit breakers in withdraw- able design necessary once for each circuit breaker. Door sealing frame IP41
3WJ1108-2AE42-4DG4-Z T40
0.0
Hết hàng
99.999.999 đ
Withdrawable circuit breaker with guide frame, IEC 60947-2, frame size 1, 4-poles, N-pole left, In=800A up to 440V AC 50/60Hz, breaking capacity S Icu=50kA at 440V, Trip unit ETU350WJ LSI Protection LT, ST, INST, rear connection horizontal, guide frame w/o shutter, Non-Automatic Breaker with manual and motorized operating mechanism (M) 208-240 V AC / 220-250 V DC, Storage status and ready-to- close signaling switches, Auxiliary switches 2NO+2NC, Closing coil (CC) 100% OP 208-240 V AC / 220-250 V DC, applicable for continuous duty, without Remote trip alarm reset coil (RR), Undervoltage release (UVR) instantaneous (0,08 s) and short-delay (0,2 s), 208-240 V AC / 220-250 V DC, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, Door sealing frame IP41
3WJ1108-2AF42-4DA4-Z T40
0.0
Hết hàng
99.999.999 đ
Withdrawable circuit breaker with guide frame, IEC 60947-2, frame size 1, 4-poles, N-pole left, In=800A up to 440V AC 50/60Hz, breaking capacity S Icu=50kA at 440V, Trip unit ETU360WJ LSIG Protection LT, ST, INST, GF, include N-protection, Requires internal current sensor for N conductor rear connection horizontal, guide frame w/o shutter, Non-Automatic Breaker with manual and motorized operating mechanism (M) 208-240 V AC / 220-250 V DC, Storage status and ready-to- close signaling switches, Auxiliary switches 2NO+2NC, Closing coil (CC) 100% OP 208-240 V AC / 220-250 V DC, applicable for continuous duty, without Remote trip alarm reset coil (RR), without 2nd shunt trip, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, Door sealing frame IP41
3WJ1108-2AF42-4DA4-Z R55+T40
0.0
Hết hàng
99.999.999 đ
Withdrawable circuit breaker with guide frame, IEC 60947-2, frame size 1, 4-poles, N-pole left, In=800A up to 440V AC 50/60Hz, breaking capacity S Icu=50kA at 440V, Trip unit ETU360WJ LSIG Protection LT, ST, INST, GF, include N-protection, Requires internal current sensor for N conductor rear connection horizontal, guide frame w/o shutter, Non-Automatic Breaker with manual and motorized operating mechanism (M) 208-240 V AC / 220-250 V DC, Storage status and ready-to- close signaling switches, Auxiliary switches 2NO+2NC, Closing coil (CC) 100% OP 208-240 V AC / 220-250 V DC, applicable for continuous duty, without Remote trip alarm reset coil (RR), without 2nd shunt trip, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, Mutual mechanical interlocking with 2 m bowden cable for circuit breakers in withdraw- able design necessary once for each circuit breaker. Door sealing frame IP41
3WJ1108-2AF42-4DG4-Z T40
0.0
Hết hàng
99.999.999 đ
Withdrawable circuit breaker with guide frame, IEC 60947-2, frame size 1, 4-poles, N-pole left, In=800A up to 440V AC 50/60Hz, breaking capacity S Icu=50kA at 440V, Trip unit ETU360WJ LSIG Protection LT, ST, INST, GF, include N-protection, Requires internal current sensor for N conductor rear connection horizontal, guide frame w/o shutter, Non-Automatic Breaker with manual and motorized operating mechanism (M) 208-240 V AC / 220-250 V DC, Storage status and ready-to- close signaling switches, Auxiliary switches 2NO+2NC, Closing coil (CC) 100% OP 208-240 V AC / 220-250 V DC, applicable for continuous duty, without Remote trip alarm reset coil (RR), Undervoltage release (UVR) instantaneous (0,08 s) and short-delay (0,2 s), 208-240 V AC / 220-250 V DC, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, Door sealing frame IP41
3WJ1108-2AE12-1AA4-Z T40
0.0
Hết hàng
99.999.999 đ
Fixed-mounted circuit breaker IEC 60947-2, frame size 1, 4-poles, N-pole left, In=800A up to 440V AC 50/60Hz, breaking capacity S Icu=50kA at 440V, Trip unit ETU350WJ LSI Protection LT, ST, INST, rear connection horizontal, Non-Automatic Breaker manual operating mechanism with mechanical request, without motorized operating mechanism, signaling switch ready-to-close, auxiliary switch (AUX) 2 NO+2 NC, without Closing coil (CC), manual operating mechanism with mechanical closing, without Remote trip alarm reset coil (RR), without 2nd shunt trip, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, Door sealing frame IP41
3WJ1108-2AE12-4DA4-Z T40
0.0
Hết hàng
99.999.999 đ
Fixed-mounted circuit breaker IEC 60947-2, frame size 1, 4-poles, N-pole left, In=800A up to 440V AC 50/60Hz, breaking capacity S Icu=50kA at 440V, Trip unit ETU350WJ LSI Protection LT, ST, INST, rear connection horizontal, Non-Automatic Breaker with manual and motorized operating mechanism (M) 208-240 V AC / 220-250 V DC, Storage status and ready-to- close signaling switches, Auxiliary switches 2NO+2NC, Closing coil (CC) 100% OP 208-240 V AC / 220-250 V DC, applicable for continuous duty, without Remote trip alarm reset coil (RR), without 2nd shunt trip, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, Door sealing frame IP41
3WJ1108-2AE12-4DA4-Z S55+T40
0.0
Hết hàng
99.999.999 đ
Fixed-mounted circuit breaker IEC 60947-2, frame size 1, 4-poles, N-pole left, In=800A up to 440V AC 50/60Hz, breaking capacity S Icu=50kA at 440V, Trip unit ETU350WJ LSI Protection LT, ST, INST, rear connection horizontal, Non-Automatic Breaker with manual and motorized operating mechanism (M) 208-240 V AC / 220-250 V DC, Storage status and ready-to- close signaling switches, Auxiliary switches 2NO+2NC, Closing coil (CC) 100% OP 208-240 V AC / 220-250 V DC, applicable for continuous duty, without Remote trip alarm reset coil (RR), without 2nd shunt trip, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, Mutual mechanical interlocking with 2 m bowden cable for circuit breakers in fixed- mounted design necessary once for each circuit breaker. Door sealing frame IP41
3WJ1108-2AE12-4DG4-Z T40
0.0
Hết hàng
99.999.999 đ
Fixed-mounted circuit breaker IEC 60947-2, frame size 1, 4-poles, N-pole left, In=800A up to 440V AC 50/60Hz, breaking capacity S Icu=50kA at 440V, Trip unit ETU350WJ LSI Protection LT, ST, INST, rear connection horizontal, Non-Automatic Breaker with manual and motorized operating mechanism (M) 208-240 V AC / 220-250 V DC, Storage status and ready-to- close signaling switches, Auxiliary switches 2NO+2NC, Closing coil (CC) 100% OP 208-240 V AC / 220-250 V DC, applicable for continuous duty, without Remote trip alarm reset coil (RR), Undervoltage release (UVR) instantaneous (0,08 s) and short-delay (0,2 s), 208-240 V AC / 220-250 V DC, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, Door sealing frame IP41
3WJ1108-2AF12-4DA4-Z T40
0.0
Hết hàng
99.999.999 đ
Fixed-mounted circuit breaker IEC 60947-2, frame size 1, 4-poles, N-pole left, In=800A up to 440V AC 50/60Hz, breaking capacity S Icu=50kA at 440V, Trip unit ETU360WJ LSIG Protection LT, ST, INST, GF, include N-protection, Requires internal current sensor for N conductor rear connection horizontal, Non-Automatic Breaker with manual and motorized operating mechanism (M) 208-240 V AC / 220-250 V DC, Storage status and ready-to- close signaling switches, Auxiliary switches 2NO+2NC, Closing coil (CC) 100% OP 208-240 V AC / 220-250 V DC, applicable for continuous duty, without Remote trip alarm reset coil (RR), without 2nd shunt trip, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, Door sealing frame IP41
3WJ1108-2AF12-4DA4-Z
0.0
Hết hàng
99.999.999 đ
Fixed-mounted circuit breaker IEC 60947-2, frame size 1, 4-poles, N-pole left, In=800A up to 440V AC 50/60Hz, breaking capacity S Icu=50kA at 440V, Trip unit ETU360WJ LSIG Protection LT, ST, INST, GF, include N-protection, Requires internal current sensor for N conductor rear connection horizontal, Non-Automatic Breaker with manual and motorized operating mechanism (M) 208-240 V AC / 220-250 V DC, Storage status and ready-to- close signaling switches, Auxiliary switches 2NO+2NC, Closing coil (CC) 100% OP 208-240 V AC / 220-250 V DC, applicable for continuous duty, without Remote trip alarm reset coil (RR), without 2nd shunt trip, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, Mutual mechanical interlocking with 2 m bowden cable for circuit breakers in fixed- mounted design necessary once for each circuit breaker. Door sealing frame IP41
3WJ1108-2AF12-4DG4-Z T40
0.0
Hết hàng
99.999.999 đ
Fixed-mounted circuit breaker IEC 60947-2, frame size 1, 4-poles, N-pole left, In=800A up to 440V AC 50/60Hz, breaking capacity S Icu=50kA at 440V, Trip unit ETU360WJ LSIG Protection LT, ST, INST, GF, include N-protection, Requires internal current sensor for N conductor rear connection horizontal, Non-Automatic Breaker with manual and motorized operating mechanism (M) 208-240 V AC / 220-250 V DC, Storage status and ready-to- close signaling switches, Auxiliary switches 2NO+2NC, Closing coil (CC) 100% OP 208-240 V AC / 220-250 V DC, applicable for continuous duty, without Remote trip alarm reset coil (RR), Undervoltage release (UVR) instantaneous (0,08 s) and short-delay (0,2 s), 208-240 V AC / 220-250 V DC, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, Door sealing frame IP41
3WJ9111-0AB01
0.0
Hết hàng
99.999.999 đ
Secondary, disconnect terminals For Fixed Design
3WJ9111-0AB02
0.0
Hết hàng
99.999.999 đ
Sliding disconnect secondary contact modules only for withdrawable design
3WJ9111-0BB12
0.0
Hết hàng
99.999.999 đ
Mechanical interlock to prevent opening of the circuit breaker compartment door, if ACB is closed; for fixed mounted design. Spare-part for Z-option S30
3WJ9111-0BB13
0.0
Hết hàng
99.999.999 đ
Mechanical interlock to prevent opening of the circuit breaker compartment door, if ACB is closed; for withdrawable design. Spare-part for Z-option R30
3WJ9111-0BA43
0.0
Hết hàng
99.999.999 đ
Key interlocking system against paralleling unsynchronized sources for 3 circuit breakers with CES lock. Interlocking in OFF position mounted to front cover 2 identical keys for 3 circuit breakers; max. 2 circuit breakers closed
3WJ9111-0BA35
0.0
Hết hàng
99.999.999 đ
Locking provision against unauthorized closing Secured Open; for with CES lock
3WJ9111-0BA31
0.0
Hết hàng
99.999.999 đ
Locking provision against unauthorized closing Secured Open; for Locking provision for CASTELL locks the lock must be ordered at the manufacturer
3RT1900-1SB60
0.0
Hết hàng
99.999.999 đ
Adhesive labels 19 x 6 mm, pastel-turquoise comprises 10 sheets A4 with 306 labels each ! Phased-out product! Successor is SIRIUS 3RT2
3RT1900-1SD60
0.0
Hết hàng
99.999.999 đ
Adhesive labels 19 x 6 mm, zinc-yellow comprises 10 sheets A4 with 306 labels each ! Phased-out product! Successor is SIRIUS 3RT2
3RT1956-4G
0.0
Hết hàng
99.999.999 đ
box terminal for 3RT1, 3RB2 frame size S6 max. connection approx. 120 mm2 3RW505
Show another 24 product